{"id":8639,"date":"2025-11-07T14:48:34","date_gmt":"2025-11-07T14:48:34","guid":{"rendered":"https:\/\/www.meddia-sarl.com\/?post_type=product&#038;p=8639"},"modified":"2025-11-07T15:00:13","modified_gmt":"2025-11-07T15:00:13","slug":"lame-chirurgicale","status":"publish","type":"product","link":"https:\/\/www.meddia-sarl.com\/?product=lame-chirurgicale","title":{"rendered":"LAME CHIRURGICALE"},"content":{"rendered":"<p><strong>Nom du produit : <\/strong>LAME CHIRURGICALE<\/p>\n<p>Les lames chirurgicales st\u00e9riles sont fabriqu\u00e9es en acier inoxydable ou en acier au carbone et fonctionnent avec une poign\u00e9e de couteau appliqu\u00e9e aux chirurgiens pratiquant l&rsquo;incision ordinaires et professionnels.<\/p>\n<p>&#8211; Selon l&rsquo;annexe \u2168 du principe 6 de la r\u00e8gle de classification MDD 93\/42 \/ CEE, ce produit appartient \u00e0 la classe II.a.<\/p>\n<p><strong>Mat\u00e9riau\u00a0: <\/strong>Acier au carbone ou acier inoxydable<\/p>\n<p><strong>Standard : <\/strong>BS2982, EN27740, EN46002, EN552<\/p>\n<p><strong>Sp\u00e9cification\u00a0: <\/strong>10#,11#,12#,13#,14#,15#,16#,17#,18#,19#,20#,21#,22#,23#,24#<\/p>\n<p><strong>Emballage\u00a0: \u00a0<\/strong>Emball\u00e9es dans des sachets en Aluminium et boites en papier.<\/p>\n<p><strong>Indications d\u2019utilisation\u00a0:<\/strong><\/p>\n<p>&#8211; Se laver les mains, porter des gants d&rsquo;examen, des masques chirurgicaux et des bonnets. &#8211; S\u00e9lectionnez la taille appropri\u00e9e de la lame et assurez-vous que l&#8217;emballage est intact et que la date de p\u00e9remption n&rsquo;a pas \u00e9t\u00e9 d\u00e9pass\u00e9e. &#8211; Ouvrez l&#8217;emballage \u00e0 une extr\u00e9mit\u00e9 et retirez la lame avec pr\u00e9caution. &#8211; Tenez l&rsquo;extr\u00e9mit\u00e9 de la tige par la main gauche et la main droite par la pince de la lame. Attachez le c\u00f4t\u00e9 arri\u00e8re de la lame et appliquez une force descendante lorsque le trou de la lame est align\u00e9 avec la rainure de la tige. Assurez-vous que la lame est compl\u00e8tement install\u00e9e sur la tige. &#8211; Tenez la tige de la lame dans les styles suivants en cons\u00e9quence pendant le fonctionnement : &#8211; Le personnel infirmier remet le manche \u00e0 lame au m\u00e9decin lors de l&rsquo;op\u00e9ration. Afin d&rsquo;\u00e9viter que le scalpel ne nuise au personnel m\u00e9dical, le scalpel doit \u00eatre pass\u00e9 en pla\u00e7ant une plaque incurv\u00e9e. &#8211; Lors du d\u00e9montage, tenez la poign\u00e9e chirurgicale dans la main gauche et le porte-lame dans la main droite, fixez le c\u00f4t\u00e9 arri\u00e8re de la lame, soulevez-le l\u00e9g\u00e8rement, poussez-le dans la rainure de la poign\u00e9e et retirez la lame.<\/p>\n<p><strong>Effets Ind\u00e9sirables\u00a0: <\/strong>&#8211; Lorsqu&rsquo;un m\u00e9decin utilise une lame chirurgicale pendant une longue p\u00e9riode, il se produit souvent une sensation de malaise, telle que l&rsquo;acidit\u00e9 du poignet, qui provoque une fatigue du poignet. Par cons\u00e9quent, il peut affecter n\u00e9gativement l&rsquo;effet chirurgical et poser un risque pour la sant\u00e9 du poignet du m\u00e9decin.<\/p>\n<p><strong>Dur\u00e9e\u00a0: <\/strong>Cinq ans.<\/p>\n<p><strong>Stockage\u00a0: <\/strong>Conservez en endroits frais, propres et secs.<\/p>\n<p><strong>Avertissement\u00a0: <\/strong><\/p>\n<p>Op\u00e9ration L\u2019utilisation de ce produit est r\u00e9serv\u00e9e \u00e0 un m\u00e9decin qualifi\u00e9 ou \u00e0 un ambulancier.<\/p>\n<p>&#8211; Lisez les instructions avant utilisation. &#8211; Le produit doit \u00eatre utilis\u00e9 conform\u00e9ment aux instructions d\u2019utilisation. &#8211; Le produit ne doit pas \u00eatre retrait\u00e9. &#8211; Inspectez visuellement et v\u00e9rifiez soigneusement le produit et son emballage avant utilisation. Un transport et une manipulation inappropri\u00e9s peuvent provoquer des dommages structurels et \/ ou fonctionnels au dispositif ou \u00e0 l\u2019emballage. &#8211; Ne l&rsquo;exposez pas \u00e0 des temp\u00e9ratures extr\u00eames, \u00e0 l&rsquo;humidit\u00e9 et aux rayons directs du soleil, car cela pourrait affecter l&rsquo;int\u00e9grit\u00e9 de la st\u00e9rilit\u00e9 de l\u2019emballage. &#8211; Le produit est garanti non toxique, st\u00e9rile et apyrog\u00e8ne si l&#8217;emballage n&rsquo;est pas ouvert ou endommag\u00e9. &#8211; Le produit doit \u00eatre utilis\u00e9 imm\u00e9diatement apr\u00e8s l\u2019ouverture de l\u2019emballage. Ne pas le rest\u00e9riliser. \u00c9liminez-le correctement apr\u00e8s usage unique. &#8211; Ne le r\u00e9utilisez pas. Si le dispositif est r\u00e9utilis\u00e9, cela peut causer de graves probl\u00e8mes \u00e0 des patients tels que le VIH, l\u2019h\u00e9patite, des maladies contagieuses, des maladies transmissibles, des maladies indues, etc.- Apr\u00e8s utilisation, veuillez mettre le produit au rebut de mani\u00e8re s\u00fbre et responsable. Assurer une \u00e9limination s\u00fbre et appropri\u00e9e des produits et emballages utilis\u00e9s \/ mis au rebut afin d&rsquo;\u00e9viter tout effet n\u00e9faste sur l&rsquo;environnement, les enfants et les animaux errants. &#8211; L&rsquo;\u00e9limination doit \u00eatre conforme aux lois en vigueur dans le pays d&rsquo;utilisation.<\/p>\n<table class=\"NormalTable\">\n<tbody>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><strong><span class=\"fontstyle0\">Statut :\u00a0<\/span><\/strong><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">NO. <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">ARTICLES <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">EXIGENCES TECHNIQUES<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">A <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">Composants Chimiques<\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">T10 : (%) C:0.95~1.04 , Si:0.15~0.35 ,Mn:0.15~0.35 ,P: \u22640.035, S:\u22640.030 , Cr:\u22640.25,Ni: \u22640.20SK: (%) C:0.90~1.00 , Si:\u22640.35 ,Mn:\u22640.50 ,P: \u22640.030, S:\u22640.030 , Cr:\u22640.20,Ni: \u22640.20SK2 : (%) C:1.10~1.30 , Si:\u22640.35 ,Mn:\u22640.50 ,P: \u22640.030, S:\u22640.030 , Cr:\u22640.20,Ni: \u22640.20<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">B <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">Solidit\u00e9 <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">\u2265750HV10<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">C <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">Acuit\u00e9 <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">\u22640.80N<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">D <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">Surface <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">Les lames chirurgicales doivent \u00eatre de niveau, elles ne doivent pas \u00eatre rouill\u00e9es, ni fissur\u00e9es; sans bavures et sans creux apparents.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">E <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">Elasticit\u00e9 <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">Il devrait \u00eatre lisse et pas de vent \u00e9vident apr\u00e8s le test.<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">F <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle0\">St\u00e9rilit\u00e9 <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">Doit \u00eatre st\u00e9rile par le rayonnement gamma<\/span><\/td>\n<\/tr>\n<tr>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">G <\/span><\/td>\n<td style=\"border-style: none\" width=\"200\">Emballage :<\/td>\n<td style=\"border-style: none\" width=\"200\"><span class=\"fontstyle2\">Nettoyez le papier d&rsquo;aluminium avec l&#8217;emballage standard.<\/span><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Les lames chirurgicales st\u00e9riles sont fabriqu\u00e9es en acier inoxydable ou en acier au carbone et fonctionnent avec une poign\u00e9e de couteau appliqu\u00e9e aux chirurgiens pratiquant l&rsquo;incision ordinaires et professionnels.<\/p>\n","protected":false},"featured_media":8530,"comment_status":"open","ping_status":"closed","template":"","meta":{"inline_featured_image":false},"product_brand":[],"product_cat":[81],"product_tag":[],"class_list":["post-8639","product","type-product","status-publish","has-post-thumbnail","product_cat-lame-de-bistouri","first","instock","shipping-taxable","product-type-simple"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=\/wp\/v2\/product\/8639","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=8639"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=\/wp\/v2\/media\/8530"}],"wp:attachment":[{"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=8639"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_brand&post=8639"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_cat&post=8639"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.meddia-sarl.com\/index.php?rest_route=%2Fwp%2Fv2%2Fproduct_tag&post=8639"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}